Bijli ka bill sirf units × ek rate nahi hota. Company, billing period, tariff code, protected/lifeline status, sanctioned load aur adjustments pehle match karein. Neeche bill verify karne ka tareeqa hai. Koi ek 300-unit amount har company aur har month ka final payable bill nahi.

1. Reading Aur Billing Period Match Karein
Same cumulative register ke liye units = (current reading − previous reading) × applicable multiplying factor. Factor bill se lein. TOU ke peak/off-peak aur net-meter ke import/export registers ko aapas mein minus na karein. Meter replacement, rollover, average billing ya outstanding units hon to simple subtraction se final verdict nahi nikalta.
Misal: old reading 14,200, new reading 14,500 aur factor 1 ho to 300 kWh. Agar readings ki dates 30 din apart hon to daily average 10 kWh hai. Agle month ki reading tak apna daily estimate isi tarah compare kar sakte hain.
2. Tariff Category Ke Mutabiq Energy Cost
Non-TOU domestic, TOU, commercial aur lifeline ek jaisi categories nahi. Protected ke one-previous-slab benefit ko non-protected par automatic apply na karein. IESCO ka February 2026 SRO 279(I)/2026 schedule dated reference deta hai. Apne billing month ka applicable notification aur provider schedule bhi check karein.
Dated example: us domestic non-TOU non-protected schedule mein 201–300 units row Rs 33.10/kWh hai. 300 × 33.10 = Rs 9,930 energy cost. Ye total bill nahi.
3. Fixed Charges Ka Base Check Karein
Isi dated example mein relevant fixed rate Rs 350/kW/month aur assumed sanctioned load 2 kW ho to fixed charge Rs 700. Energy + fixed = Rs 10,630. Apne meter ki phase count ya ghar ka size dekh kar load 2 kW assume na karein. TOU aur doosre tariffs ke billing-demand rules alag ho sakte hain.
4. FCA/QTA Ko Un Ke Period Aur Applicability Se Milayen
Bill mein har adjustment ki line ke saath rate, charged units, reference period aur recovery month note karein. Har FCA/QTA har category ya har month par ek jaisa nahi. Positive debit aur negative credit ko sahi sign ke saath rakhein. Purane article ka “current FCA” agle bill ke liye copy na karein.
Sirf arithmetic ki misal: agar applicable adjustment +Rs 1.20/kWh ho aur 300 eligible units hon to +Rs 360. Agar ek doosri applicable adjustment −Rs 0.50/kWh ho to −Rs 150. Net adjustment +Rs 210. Ye assumed rates hain, current notified rates ka claim nahi.
5. Taxes, Fees, Arrears Aur Credits Alag Rakhein
GST ka applicable taxable base, electricity duty, financing surcharge, income tax aur doosri lines ko apne bill aur relevant rules se match karein. Puri amount payable par ek flat GST laga dena har case ka correct method nahi. PTV fee ya kisi disputed charge ko sirf is guide ki bunyaad par automatically illegal/billing error na samjhein; applicable period aur notification mangwain.
Current-period charges, previous arrears, already-paid amount, instalments, credit adjustments aur late-payment surcharge alag columns mein likhein. Total charges aur outstanding amount ek cheez nahi. Payment proof ke bawajood arrears nazar ayen to receipt/reference ke saath reconciliation mangwain.
Apne Bill Ki Reconciliation Sheet
| Entry | Aap kya likhein? |
|---|---|
| Reading/units | Dates, registers, multiplying factor, actual ya average |
| Energy | Category, applicable schedule, slab/TOU calculation |
| Fixed | Rate × applicable load/billing demand |
| Adjustments | Har FCA/QTA ka rate, eligible units, period aur debit/credit |
| Other current charges | Taxes, duties aur fees ki separate bill lines |
| Account balance | Arrears + instalments + LPS − paid/credited amount |
Calculator Aur Official Bill Ka Farq
Electricity Bill Calculator ke assumptions/date aur included/excluded items pehle dekhein. Ye bill retrieve nahi karta aur har account ki levy, credit ya adjustment certify nahi karta. Dated unit examples aur official bill links se line-by-line compare karein.
Checked 13 November 2026. Reference example February 2026 schedule par scoped hai. Current month ka final amount official company bill aur applicable notifications se reconcile karein.