10kW Solar System Mahine Mein Kitne Units Banata Hai?

10 kW solar ka monthly output ek fixed Pakistan-wide number nahi. Pehle clarify karein ke 10 kW panels ki DC nameplate capacity hai ya inverter ki AC rating. Location, weather month, tilt/azimuth, shade, temperature, inverter clipping, downtime aur losses se delivered AC kWh change hoti hai.

10kw solar system kitne units banata hai — ghar ki chhat par lage solar panels

Planning Formula, Guarantee Nahi

Rough energy = panel DC kWp × equivalent full-sun hours/day × days × overall delivery factor. Ordinary daylight duration ko full-sun hours na samjhein. Example mein 10 kWp × assumed 5 equivalent hours × 30 days × assumed 0.80 factor = 1,200 kWh/month. Agar factor already includes a loss category to usay dobara deduct na karein.

Assumed equivalent sun-hours/daySame 10 kWp, 30 days, 0.80 factor
4960 kWh
51,200 kWh
61,440 kWh

Ye sensitivity inputs hain, Lahore/Karachi/Islamabad ki verified city forecasts nahi. Har winter par fixed 20–30% reduction ya har roof par guaranteed 1,200–1,400 units na lagayen.

NREL PVWatts location/weather, DC size, orientation, losses aur inverter assumptions se grid-connected AC-energy estimate banata hai. Ek generic 120 units/kW/month ko har Pakistani roof ki measured average ya guaranteed minimum na kahein. Monthly/hourly estimates aur actual inverter record ko priority dein.

585 W Panels Se Exact DC Size

17 × 585 W = 9,945 W = 9.945 kWp, exact 10 kWp nahi. Upar wale 5-hour/0.80 assumptions par 9.945 × 5 × 30 × 0.80 = 1,193.4 kWh. Ek 585 W module ki same assumed energy 0.585 × 5 × 30 × 0.80 = 70.2 kWh/month hai, 2.34 kWh/day average. Nameplate watts se poore din wahi power deliver hone ka claim nahi.

Production, Load Capacity Aur Backup Alag Hain

Monthly 1,200 kWh ka estimate ye prove nahi karta ke 2–3 AC, pump aur saara ghar har waqt chal jayega. Inverter AC rating, motor start/surge, instantaneous PV output, grid availability aur battery usable kWh alag check karein. Ordinary grid-following system ka monthly production outage backup guarantee nahi.

Payback Ka Arithmetic Sahi Rakhein

Hypothetical installed quote Rs 13,00,000 aur net saving Rs 30,000/month ho to simple payback = 13,00,000 ÷ (30,000 × 12) = 3.61 years. Assumed saving Rs 20,000/month ho to 5.42 years. In figures ko current installed-market price ya guaranteed saving na samjhein. Savings ko bill-before/bill-after se derive karein; warranty length future profit guarantee nahi.

Regulatory reference: NEPRA Prosumer Regulations 2026, regulation 14 import ko applicable tariff aur export ko National Average Energy Purchase Price se relate karti hai, aur notified rate revision ki provision rakhti hai. Is se Rs 8.13 permanently fixed statutory rate prove nahi hota. Apna agreement, applicable amendments aur current notified/credited rate NEPRA legal index aur provider se match karein. Legacy agreement ko current/new account ke saath automatic same model na samjhein.

Installer Se Useful Production Report Mangwain

Model location/weather source, exact module count/DC capacity, AC inverter, DC/AC ratio, shade, azimuth/tilt aur monthly AC kWh assumptions documented hon. “10 kW, 1,500 units guaranteed” ke bajaye acceptance conditions aur exclusions written hon. Planning calculator simple scenario hai, detailed roof simulation/backup design nahi.

Formula, panel-count and simple-payback examples checked 13 November 2026. Figures illustrative assumptions hain.