Apne numbers daalein. Hisaab samjhein.

Solar System Size & Payback Calculator — Solar Laganay Ka Kharcha Aur Munafa Maloom Karein

Aap ka result
—

Rates ka source: NEPRA Prosumer Regulations 2026, SRO 251(I)/2026 (net billing, eff. 9 Feb 2026); system cost ke andazay editable hain · Laago date: 2026-02-09

Is calculator ko apni website pr lagayen — bilkul free

Neeche wala code copy kr ke apni website ya blog me paste karen — ye calculator wahan hi chal parega. Calculator ke neeche Calculators33 ka chhota sa link ata hai. Height (560) apni site ke hisab se badal sakte hain.

Yeh monthly energy aur entered prices ka planning model hai. Monthly units se rough system size aur simple payback compare hota hai. Roof design, sanctioned-load permission, hourly matching, battery design aur final electricity bill ka complete engineering model nahi.

solar system size calculator

Size, Self-Use Aur Export Ka Hisaab

Rough kW = monthly consumption ÷ entered generation per kW/month; result nearest 0.5 kW par round hota hai. Generation = selected kW × entered generation. Pakistan ke har roof par 120 units/kW/month guaranteed nahi: location, shade, orientation, season, equipment aur losses se output badalta hai.

Model self-use = generation × entered self-use percentage, monthly household consumption se capped. Remaining model generation export hai. Yeh monthly cap hourly coincidence, grid outages ya legal export permission prove nahi karta. Battery losses aur usable storage complete simulate nahi hote.

Default Inputs Ki Checked Example

Model input / resultAmount
Consumption / generation assumption600 units; 120 units per kW/month
Rough size / generation5 kW / 600 units
Illustrative on-grid installation input5 × Rs 130,000 = Rs 650,000
60% self-use, assumed avoided cost Rs 45360 × 45 = Rs 16,200
40% export, entered credit Rs 8.13240 × 8.13 = Rs 1,951.20
Monthly modelled energy valueRs 18,151.20
Simple payback650,000 ÷ 18,151.20 = 35.8 months

Rs 130,000/kW, Rs 45 avoided rate aur Rs 8.13 export credit yahan model inputs hain, aaj ki installer quote ya guaranteed official tariff nahi. Isi default scenario ko 100% self-use karne par monthly value Rs 27,000, export zero aur simple payback 24.1 months hota hai. Future actual performance ki guarantee nahi.

Buyback Rate Aur Agreement Ko Alag Verify Karein

New net-billing ya legacy mode apne actual connection/agreement se match karein. Entered buyback rate ko current NAEPP ya apne legacy contract ka automatic entitlement na samjhein. Fixed default Rs 25.32 bhi har legacy account ki guaranteed settlement rate nahi. NEPRA ke current regulations aur amendments, DISCO/KE agreement aur latest settlement statement se applicable basis confirm karein.

Bill ÷ Units Hamesha Avoided Unit Cost Nahi

Average bill rate mein fixed charges, adjustments aur taxes shamil ho sakte hain jo solar ke baad poore nahi bachte. Self-use field mein entered rate assumed avoided energy cost hai. Behtar comparison ke liye same billing category aur period par solar se pehle/baad import units ka bill alag calculate karein. Export credit ko poora cash saving ya full final-bill cancellation na samjhein.

Total Investment Aur Fee Ka Scope

Written installer quote se panels, inverter, compatible battery if needed, structure, installation, protections, wiring, approvals aur excluded fees match karein. Result ki fee allowance model configuration hai, current legal fee exemption/charge ki certification nahi. Official demand notice aur applicable rule verify karke omitted cost apni investment comparison mein add karein. Hybrid label se exact battery capacity, backup hours ya every replacement cost included hone ka proof nahi milta.

10/25-Year Numbers Ka Matlab

Yeh configured panel degradation aur entered rates par gross energy-value projections hain, net profit nahi. Maintenance, replacement battery/inverter, financing, downtime, tariff changes aur future export settlement complete included nahi. In costs ko ignore karne se payback optimistic ho sakta hai. Simple payback time value of money ya discounted cash flow bhi model nahi karta.

Decision Se Pehle Checklist

  • Same-scope written quotes aur exact component models compare karein.
  • Roof/shade survey, sanctioned load aur applicable export approval confirm karein.
  • Hourly daytime consumption aur seasonal generation estimate lein.
  • Self-use/rates ko low, middle aur high assumptions par dobara run karein.
  • Battery backup chahiye to separate load/battery estimate aur installer design match karein.

Mazeed Rehnumai (Guides)

Aap ke sawal

Common questions

Mahana 600 units ke liye kitne size ka solar system chahiye?
Pakistan mein aik kW mahana taqreeban 120 units banata hai, is liye 600 units ke liye taqreeban 5 kW system chahiye. Tool size ko qareeb tareen 0.5 kW tak round karta hai aur recommendation ko aap ke istimal tak mehdood rakhta hai.
2026 mein net billing se kya badla?
Net metering ki jagah net billing aa gayi (NEPRA Prosumer Regulations 2026, 9 Feb 2026 se): export kiye gaye units ab imported units ko 1:1 cancel nahi karte — wo kam buyback rate par khareeday jatay hain (naye sarifeen ke liye taqreeban Rs 8.13/unit), jabke jo units aap khud istimal karte hain wo pura retail rate bachate hain.
Self-consumption itni ahem kyun hai?
Khud istimal kiya gaya aik unit aap ko retail bill ke Rs 40–50 bachata hai; export kiya gaya unit sirf taqreeban Rs 8 kamata hai. Din ke waqt bhari cheezein chalane se self-consumption barhti hai aur payback jaldi hota hai.
5 kW system apni lagat kitne arsay mein poori kar leta hai?
October 2026 ki qeematon (on-grid taqreeban Rs 130,000 per kW) aur 60% self-consumption par, mahana taqreeban Rs 18,151 bachane wala 5 kW system taqreeban 36 mahinon mein apni lagat poori kar leta hai — tool ye hisab aap ke apne inputs se dobara lagata hai.